Interface 1000 Fatigue Series

The Interface 1000 Fatigue rated series is a long established favorite for aerospace & automotive test rigs where a high number of repetitive cycles are required over a period of time that can stretch to several years. The warranted life of Interface 1000 series Low Profile load cells is a minimum of 100 Million fully reversed cycles at full rated load. The manufacturing process of these units involves additional measures to reduce high stress points and routing of internal components through zero stress areas to ensure the longest possible lifespan under the most demanding test conditions.

  • Fatigue Rated
  • Capacities from 1.25kN to 225kN (250lbf to 50klbf)
  • High output to 2.0mV/V
  • Moment compensated
  • Performance to 0.03%
Interface 1000 Fatigue Series

Available Downloads:

  • Warranted performance to 0.06%
  • 14 capacities from 1.25kN to 4.5MN (250lbf to 1,000Klbf)
  • High output to 2.0 mV/V for best resolution
  • Moment compensation for enhanced insensitivity to extraneous loads
  • Excellent temperature characteristics
  • Extra low deflection
  • Individual multi-point calibration certificate traceable to National Standards
PARAMETERSMODEL
1010101010201032
CAPACITY
Measuring RangeU.S. (lbf)2.5K, 5K250, 500, 1K7.5K, 10K, 12.5K, 25K50K
Metric (kN)12.5, 251.25, 2.5, 533.4, 44.5, 50, 125225
ACCURACY - (MAX ERROR)
Static Error Band - %FS±0.04±0.03±0.04±0.05
Nonlinearity - %FS±0.04±0.04±0.04±0.05
Hysteresis - %FS±0.04±0.03±0.05±0.05
Non-repeatability - %RO±0.02±0.02±0.02±0.02
Creep, in 20 min - %±0.025±0.025±0.025±0.025
Side Load Sensitivity - %±0.1±0.1±0.1±0.1
Eccentric Load Sensitivity - % / in±0.1±0.1±0.1±0.1
TEMPERATURE
Compensated Range°F+14 to +113+14 to +113+14 to +113+14 to +113
°C-10 to +45-10 to +45-10 to +45-10 to +45
Operating Range°F-67 to +194-67 to +194-67 to +194-67 to +194
°C-55 to +90-55 to +90-55 to +90-55 to +90
Effect on Zero - %RO MAX°F±0.0008±0.0008±0.0008±0.0008
°C±0.0014±0.0014±0.0014±0.0014
Effect on Output - %RO MAX°F±0.0008±0.0008±0.0008±0.0008
°C±0.0014±0.0014±0.0014±0.0014
ELECTRICAL
Rated Output - mV/V (Nominal)2122
Bridge Resistance - Ohm (Nominal)350350350350
MECHANICAL
Safe Overload - %CAP±300±300±300±300
Deflection @ ROin0.0010.00050.0010.002
mm0.0250.0130.0250.051
Optional Base - P/N (Metric)B101(M)B101(M)B102(M), B103(M)B112(M)
Natural Frequency - kHz5.0, 6.9, 9.85.0, 6.9, 9.86.6, 9.45.8
Weightlb1.51.53.326
kg0.680.681.511.79
MaterialAluminumAluminumAlloy SteelAlloy Steel
CalibrationTension & Compression

  • Multiple independent bridge outputs
  • Base supplied fitted (recommended)
  • Integral cable or choice of connector(s)
  • Standardised output
  • ID Chip or TEDS (Transducer Electronic Data Sheet)
  • Special thread sizes
  • Enhanced performance characteristics
  • Special fittings
  • Mechanical adaptations
  • A2LA accredited calibration
  • Display electronics or data acquisition
  • Load cell with/without fitted base
  • Connector output versions supplied with mating part(s)
  • NIST traceable multi-point calibration certificate

Why choose Interface Sensor Products?

Interface is an internationally recognised brand and decades of experience have gone into making Interface manufactured load cells the benchmark for thousands of users around the world.

Interface product reliability is second to none and all our product lines have to match this standard before we would consider recommending them to our customers.

Our customer list is a "Who's Who" of household names ranging from the Aerospace Giants through to the most prestigious Universities. This speaks volumes about our reputation for quality solutions on projects of all sizes around the world.

Back To Top