Interface 1100 Ultra Precision Load Cells

The 1100 Ultra-Precision series is an enhanced version of our standard Low Profile load cell to provide the extra warranted performance required for more demanding applications. The 1100 is supplied with a fitted base to remove any uncertainties regarding mounting arrangements and to guarantee the performance under normal working conditions. The 1100 series is an ISO376 capable device and can be used as a calibration load cell with the addition of an optional calibration adaptor.

  • Performance to 0.02%
  • High output - to 4mV/V
  • Capacities from 1.5kN to 900kN
  • High precision base included
  • Tension and compression
Interface 1100 Ultra Precision Load Cells

Available Downloads:

  • Warranted performance to 0.02%
  • 10 capacities from 1.5kN to 900kN (300lbf to 200Klbf)
  • High output to 4.0 mV/V for highest resolution
  • Moment compensation for enhanced insensitivity to extraneous loads
  • Excellent temperature characteristics
  • Low deflection
  • Individual multi-point calibration
  • Certificate traceable to National Standards
PARAMETERSMODEL
11101110112011321140
CAPACITY
Measuring RangeU.S. (lbf)5K, 10K300, 500, 1K, 2K, 3K15K, 20K, 25K, 50K100K200K
Metric (kN)25, 501.5, 2.5, 5, 1066.7, 89, 100, 250450900
ACCURACY - (MAX ERROR)
Static Error Band - %FS±0.03±0.02±0.035±0.04±0.06
Nonlinearity - %FS±0.035±0.03±0.035±0.04±0.06
Hysteresis - %FS±0.04±0.02±0.045±0.04±0.06
Non-repeatability - %RO±0.01±0.01±0.01±0.01±0.01
Creep, in 20 min - %±0.025±0.025±0.025±0.025±0.025
Side Load Sensitivity - %±0.1±0.1±0.1±0.1±0.1
Eccentric Load Sensitivity - % / in±0.1±0.1±0.1±0.1±0.1
TEMPERATURE
Compensated Range°F+14 to +113+14 to +113+14 to +113+14 to +113+14 to +113
°C-10 to +45-10 to +45-10 to +45-10 to +45-10 to +45
Operating Range°F-67 to +194-67 to +194-67 to +194-67 to +194-67 to +194
°C-55 to +90-55 to +90-55 to +90-55 to +90-55 to +90
Effect on Zero - %RO MAX°F±0.0008±0.0008±0.0008±0.0008±0.0008
°C±0.0014±0.0014±0.0014±0.0014±0.0014
Effect on Output - %RO MAX°F±0.0008±0.0008±0.0008±0.0008±0.0008
°C±0.0014±0.0014±0.0014±0.0014±0.0014
ELECTRICAL
Rated Output - mV/V (Nominal)42444
Bridge Resistance - Ohm (Nominal)350350350350350
MECHANICAL
Safe Overload - %CAP±150±150±150±150±150
Deflection @ ROin0.0040.0020.0040.0060.012
mm0.1020.0510.1020.1520.305
Optional Base - P/N (Metric)B102(M)B101(M)B103(M)B112(M)B105(M)
Weightlb9.41.1246262
kg4.260.510.8928.1228.12
MaterialAluminumAluminumAlloy SteelAlloy SteelAlloy Steel
CalibrationTension & Compression

  • Multiple independent bridge outputs
  • Standardised output
  • Integral cable or choice of connector(s)
  • Special thread sizes
  • ID Chip or TEDS (Transducer Electronic Data Sheet)
  • Special fittings
  • Enhanced performance characteristics
  • A2LA accredited calibration
  • Mechanical adaptations
  • ISO/ASTM or MILSPEC calibration
  • Display electronics or data acquisition
  • Load cell with fitted base
  • Connector output versions supplied with mating part(s)
  • NIST traceable multi-point calibration certificate

Why choose Interface Sensor Products?

Interface is an internationally recognised brand and decades of experience have gone into making Interface manufactured load cells the benchmark for thousands of users around the world.

Interface product reliability is second to none and all our product lines have to match this standard before we would consider recommending them to our customers.

Our customer list is a "Who's Who" of household names ranging from the Aerospace Giants through to the most prestigious Universities. This speaks volumes about our reputation for quality solutions on projects of all sizes around the world.

Back To Top